Effective piston area. The default value is 0.001
m^2.
Piston maximum travel between caps. The default value is 0.1
m.
Method for determining the piston position. The default value is Calculate from velocity of port R relative to port C
, which calculates the position internally and reports the position at port p. The block can also receive the position at port p from a Multibody block when set to Provide input signal from Multibody joint
.
The distance between the piston and cap at the beginning of simulation. This value cannot exceed the piston stroke. The default value is 0
, which corresponds to the fully retracted position. To enable this parameter, set Piston displacement to Calculate from velocity of port R relative to port C
.
Fluid volume that remains in the chamber after the rod is fully retracted. The default value is 1e-4
m^3.
Pressure in the cylinder chamber at the beginning of simulation. The default value is 0
.
Gas-specific heat ratio for the Hydraulic Piston Chamber block. The default value is 1.4
.
Specifies the elastic property of colliding bodies for the Translational Hard Stop block. The greater the value of the parameter, the less the bodies penetrate into each other, the more rigid the impact becomes. Lesser value of the parameter makes contact softer, but generally improves convergence and computational efficiency. The default value is 1e6
N/m.
Specifies dissipating property of colliding bodies for the Translational Hard Stop block. At zero damping, the impact is close to an absolutely elastic one. The greater the value of the parameter, the more energy dissipates during an interaction. Keep in mind that damping affects slider motion as long as the slider is in contact with the stop, including the period when slider is pulled back from the contact. For computational efficiency and convergence reasons, MathWorks recommends that you assign a nonzero value to this parameter. The default value is 150 N*s/m.
Modeling approach for hard stops. Options include:
Stiffness and damping applied smoothly through transition region
(default) — Scale the magnitude of the contact force from zero to its full value over a specified transition length. The scaling is polynomial in nature. The polynomial scaling function is numerically smooth and it produces no zero crossings of any kind.
Full stiffness and damping applied at bounds, undamped rebound
— Apply the full value of the calculated contact force when the hard-stop location is breached. The contact force is a mix of spring and damping forces during penetration and a spring force—without a damping component—during rebound. No smoothing is applied.
Full stiffness and damping applied at bounds, damped rebound
— Apply the full value of the calculated contact force when the hard-stop location is breached. The contact force is a mix of spring and damping forces during both penetration and rebound. No smoothing is applied. This is the hard-stop model used in previous releases.
Distance below which scaling is applied to the hard-stop force. The contact force is zero when the distance to the hard stop is equal to the value specified here. It is at its full value when the distance to the hard stop is zero. The default value is 1 mm
..
Specifies cylinder orientation with respect to the globally assigned positive direction. The cylinder can be installed in two different ways, depending upon whether it exerts force in the positive or in the negative direction when pressure is applied at its inlet. If pressure applied at port A exerts force in negative direction, set the parameter to Pressure at A causes negative displacement of R relative to C
. The default value is Pressure at A causes positive displacement of R relative to C
.
Restricted Parameters
Parameter determined by the type of working fluid:
Fluid bulk modulus
Use the Hydraulic Fluid block or the Custom Hydraulic Fluid block to specify the fluid properties.
The block has the following ports:
A
Hydraulic conserving port associated with the cylinder inlet.
R
Mechanical translational conserving port associated with the cylinder rod.
C
Mechanical translational conserving port associated with the cylinder clamping structure.
p
Physical signal input port that receives rod extension from a Multibody block. To expose this port, set Piston displacement to Provide input signal from Multibody joint
.
p
Physical signal output port that returns the rod position with respect to port C. To expose this port, set Piston displacement to Calculate from velocity of port R relative to port C
.